Engineering pre-selection for chemical duty pumps
MEDIA GUIDE

Methanol Pumps

Flammable, toxic and thirsty for the wrong elastomer — the containment decision leads.

The properties that drive the choice

Hazard profileflammable, toxic
Concentration band in our dataany (not banded)
In one lineFlammable + toxic — zero-leakage (magnetic/canned) drive strongly recommended; check elastomer compatibility (use PTFE/FFKM seals).

Which pump families serve it

At a reference duty (20 °C, 10 m³/h, 30 m). Your duty point may move the answer — run it through the tool below; the full report adds the alternatives worth quoting in parallel.

Primary answerMagnetic Drive Centrifugal Pump (Metallic, sealless)Toxic, flammable, expensive or environmentally sensitive fluids — zero leakage
Typical wetted materialsStainless Steel 304, Stainless Steel 316L

Where the boundaries sit

  • Toxic and flammable: leakage is a safety event, so containment is the first selection gate
  • Methanol attacks some elastomers and plastics; the soft parts need the rating check, not only the metal
  • Water content changes both the chemistry and the fire behaviour — state the grade

Related reading

Pumping this fluid? The selector on the home page maps your concentration, temperature and duty point to a pump type and wetted materials for this exact medium — free. Open the tool →