Engineering pre-selection for chemical duty pumps
PUMP FAMILY

Progressing Cavity Pump

The viscous-duty answer — steady, low-shear flow that centrifugal hydraulics cannot deliver past the 500 cP line.

Gentle, pulse-free handling of viscous or shear-sensitive media.

The envelope

Recommended temperature≤ 120 °C
Delivered-evidence ceiling~150 °C (special builds)
SealingSingle mechanical seal (or packing), per media
Design basisAPI 676 (rotary positive displacement)

Where it is used

  • Viscous fluids: polymers, resins, pastes, sludges, glycerin-class duties
  • Slurries and shear-sensitive fluids where a gentle, pulsation-free flow matters
  • Metered transfer where the flow must stay steady against changing back-pressure

Where it stops

  • The stator is a wearing part by design — dry running destroys it in seconds
  • Abrasive service wears both rotor and stator; the spare-parts plan is part of the selection
  • High speeds on viscous duty heat the stator; speed selection is a thermal decision

Documented service reaches about 150 °C on suitable stator compounds; the recommendation zone ends at 120 °C.

Related reading

Running a duty point? The selector on the home page maps your fluid, concentration, temperature and duty point to a pump type and wetted materials — free. Open the tool →